The VITA® kit for diagnosis of American foulbrood was developed on behalf of Vita (Europe) Limited by the Pocket Diagnostics section of the Central Science Laboratory in York, UK. It is designed to provide rapid on-site diagnosis of possible infection of bee larvae by American foulbrood. AUTHORIZED PRODUCT for VETERINARY USE.
Instructions for use Performing the test: Step-by-step illustrations Interpretation of resultsAfter 3 minutes, the control line should be clearly visible in the display window of the device. A positive result (indicated by the appearance of both the test line and the control line-see below) indicates that the pathogen sought is present in the sample, and that the larva taken was infected with American foulbrood. Note that even a faint T-line indicates a positive result.A negative result (only appearance of the control line, test line absent) indicates that the sample does not have American foulbrood pathogens. A negative test result does not guarantee the absence of AFB infection in some other part of the colony than the sample tested. Choose the sample with the utmost care.
Instructions for use Extraction: Use the supplied spatula to extract three whole larvae showing suspicious symptoms. Unscrew the lid of the extraction bottle. Deposit the larvae into the bottle, again using the spatula. Shake vigorously so that the larvae soak into the buffer solution. CAUTION - The bottle contains buffer solution and sodium azide; not to be used for human use. Carefully screw the lid back on and shake vigorously for about 20 seconds so that the larvae mix well with the buffer solution. Performing the test: Remove a test device from the aluminum package. WARNING Do not touch the viewing window. Unscrew the lid of the bottle and with the dropper provided, take a good amount of solute. For best results, draw out the solute immediately after shaking so as to prevent bacteria from settling out of the suspension. Hold the device horizontally and gently drop 2-3 drops into the 'well provided. Hold the device horizontally until the extract is absorbed (about 30 seconds) and blue coloration appears in the display window. Wait until the control line (indicated by the letter C) appears and read the result (about 1-3 minutes). Take care to dispose of the test in an environmentally friendly manner. At low temperatures, the test takes longer; the ideal temperature for the test is 18°C and above. Interpretation of resultsAfter 3 minutes, the control line should be clearly visible in the display window of the device. A positive result (indicated by the appearance of both the test line and the control line-see below) indicates that the pathogen sought is present in the sample, and that the larvae taken has been infected with American foulbrood. Note that even a faint T-line indicates a positive result.A negative result (only appearance of the control line, test line absent) indicates that the sample does not have American foulbrood pathogens. A negative test result does not guarantee the absence of AFB infection in some other part of the colony than the sample tested. Choose the sample with the utmost care.
APIVAR- Beehive strips for bees , 10-pack. product features in section (DOWNLOAD) How Apivar worksThe active ingredient amitraz has insecticidal and acaricidal activity by contact.It inhibits neuronal transmission causing neurotoxicity. The parasite becomes paralyzed and is eliminated naturally by gravity in the environment.Apivar is therefore indicated for the prevention and treatment of external parasite disorders due to Varroa jacobsoni or Varroa destructor.How to use ApivarUse 2 strips of Apivar per Beehive (10 frames). Separate the double stripand arrange each strip between two movable frames in the rearing chamberor between groups of bees, keeping a distance of two frames between one strip and the other. Suspend product treatment in the rearing chamber so that bees can move to both sides of the strip.
The 3M 6200 reusable semi-mask respirator is easy to use, lightweight and requires minimal maintenance. Filters are supplied separately. The nape cap is designed to ensure a snug fit and to make it easy to fasten behind the neck. The soft elastomeric facepiece and light weight (82 g) provide excellent comfort even for prolonged periods of work. The compact design minimizes obstruction of the field of view and makes it easy to handle. The two-side filter attachment system provides minimal resistance to breathing.